4154353.pdf

Electrolux EUCAIDP - Zmywarka wycza si po kilku sekundach.

Andrzeju sprawd czy kto nie poprzestawia parametrw. Ten service jest do wielu zmywarek. Twj to PROG 106 do EUCAIDP 502026


Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

SERVICE MANUAL

3.__

3..__

TANK
BOILER

CONTENTS:

TANK
BOILER

This document contains the instructions to set electronic board parameters via user
interface for following dishwashers:

CODE

MODEL

CODE

MODEL

CODE

MODEL

CODE

MODEL

400041

NUC3DD

400155

NUC1DPDD

504233

EHTAIG

506054

EPPWELG

400055

EUC1

502010

NUCAIG

504234

EHTAIWSG

506055

EPPWELG60

400056

EUC1DP

502011

NUCAIWSG

504235

EHTAIAU

506056

ZPPWELG

400057

EUC1WS

502025

EUCAI

504236

EHTAIMLAU

506057

ZPPWSLG

400058

EUC1DPWS

502026

EUCAIDP

504237

ZHTAWS

511326

NPPWESG

400059

EUC3

502027

EUCAI60

504238

ZHTAID

511328

NPPWEGH

400060

EUC3WS

502028

EUCAIWS

504239

ZHTAIWS

511329

NPPWELG

400061

EUC3DP

502033

EUCAIG

504240

ZHTAIAU

690028

NUC1G

400062

EUC3DPWS

502034

EUCAIWSG

504241

ZHTA

698005

NUCA1DDG

400063

EUC1G

502035

EUCAIML

504242

ZHTA60

698047

OHTAROW

400064

EUC1DP60

502036

EUCAIMLWS

504243

ZHTAI

698048

OHTAROW60

400065

EUC3DD

502037

EUCAIMLG

504244

EHTAIUSPH5

698049

NUCA1DPDDG

400066

ZUCADDROW

502038

EUCAICL

504245

EHTAIUSPH6

698058

NHTDPDDG

400067

ZUCADDROW6

502039

EUCAICLG

505036

EHTAO

698083

APPWELG

400068

EUCADD60

502040

EUCAIWL

505046

EHT

698085

APPWESG

400116

FUCA3DD

502042

EUCAICLW

505047

EHT60

698086

APPWEHG

400120

NUC1DPP

502043

EUCI

505048

EHTAG

698087

ET5AIIT

400122

NUC1DUK

502044

EUCIM

505049

EHTM

698088

ET5AIDP

400123

NUC1DDUK

502045

EUCIM60

505050

EHTM60

698089

ET5AIDPWS

400127

KUC3

502046

EUCAIDPNW

505051

NHT

698091

AUCI

400128

KUC3DP

502047

ZUCI

505052

NHTD

698092

AUCAI

400130

NUC1DDRUKP

502048

ZUCID

505053

NHT60

698093

AUCAIDP

400131

NUC1GRUK

502049

ZUCAI

505054

EHTAROW

698094

AUCAIDPWS

400133

NUC1D

502050

ZUCAIDP

505055

EHTAROW60

698095

AUCAIG

400134

NUC1DD

502051

ZUCAIDPWS

505056

ZHTAROW

698096

AUCAIWSG

400137

EUCA1DP

502052

ZUCAIG

505057

ZHTAROW60

698097

ET12AI

400138

NUC1GMS

502053

ZUCAIDDWS

505058

EHTAJ

698098

ET12AIT

400139

EUC3DPCAG

502054

ZUCAID

505059

EHTAJ60

698110

NHTAG

400140

NUC1

502055

ZUCAI60

505060

EHTAO60

698115

AHTAWS

400141

NUC1DP

502056

EUCAIUSPH6

505061

ZHTAO

698116

AHTAIWS

400142

NUC1WS

502057

ZUCAIDD

505062

ZHTAO60

698117

AHTAIG

400143

NUC1WSDP

502058

EUCAIDD

505063

KHT

698118

AHTAIWSG

400144

NUC3

502059

EUCAIDPJ

505064

NHTM

698119

AHTA

400145

NUC3WS

502060

EUCAIDPJ60

505065

NHTM60

698120

AHTAI

400146

NUC3DP

502123

EUCIDDC

505082

NHTP

S49JGF

400147

NUC3DPWS

502124

ZUCIDC

505087

ZHT7

S49LBN

400148

NUC3DDWS

504226

EHTA

505088

ZHT76

S49QL1

400149

NUC1DP60

504227

EHTA60

506048

EPPWESG

400150

NUC1DPA

504228

EHTAWS

506049

EPPWESG60

400151

ZUCA1

504229

EHTAI

506050

EPPWEHG

400152

ZUCA3

504230

EHTAID

506051

ZPPWESG

400153

EUCADDROW

504231

EHTAIWS

506052

ZPPWEHG

400154

EUCADDROW6

504232

EHTAIDWS

506053

ZPPWSSG

EDITION:
DOC. NO. 5956.65J.00

12.2014
P. 1 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

INDEX
1

Pag.

3

HOOD TYPE Style

Pag.

3

1.2
2

KEYBOARDS
1.1

UNDERCOUNTER Style

Pag.

4

MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS

Pag.

5

2.1

Detergent Dispenser Activation

Pag.

5

2.2

Rinse Aid Dispenser Activation

Pag.

5

3

RINSE PUMP MANUAL ACTIVATION

Pag.

5

4

DETERGENT AND RINSE AID DOSAGE

Pag.

6

Pag.

6

5

COUNTERS

Pag.

8

5.1

Cnt Counters

Pag.

8

TEMPERATURE SETTING

Pag.

10

6.1

Pag.

10

CYCLE SETTING

Pag.

12

7.1

CYCLE DIAGRAM

Pag.

13

7.2

CY1 Cycle 1 Parameters

Pag.

14

7.3

CY2 Cycle 2 Parameters

Pag.

14

7.4

CY3 Cycle 3 Parameters

Pag.

14

7.5

drn Drain/Cleaning Cycle Parameters

Pag.

15

OTHER PARAMETERS

Pag.

15

8.1

dPA Dishwashing Parameters

Pag.

15

8.2

ron Read Only Parameters

Pag.

16

8.3

HCP Communication and HACCP Parameters

Pag.

16

8.4

CFG Configuration Parameters

Pag.

17

8.5

dbG Parameters for automatic hood type dishwashers

4.1

6
7

8

GEn General Parameters

FAC Factory Parameters

Pag.

18

SPECIAL FEATURES

Pag.

20

9.1

RESIN REGENERATION CYCLE

Pag.

20

9.2

MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE

Pag.

20

9.3

DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION

Pag.

20

9.4

DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER

Pag.

21

9.5

HOOD-TYPE DISHWASHER WITH CYCLE THERMAL LABEL

Pag.

22

9.6

DISHWASHERS WITH WASH TANK WATER CHANGE FREQUENCY CONTROL

Pag.

22

9.7

9

PERISTALTIC TUBE FITTING AND REPLACEMENT INSTRUCTIONS

Pag.

23

MAIN BOARD CONFIGURATION

Pag.

26

10.1

CODE - & gt; Prog. TABLE

Pag.

26

10.2

10

PROGRAMMING SHEETS

Pag.

28

11

DEFAULT VALUES

Pag.

120

12

USER INTERFACE AND MAIN BOARD CONNECTORS

Pag.

123

12.1
13

Main malfunctions not due to the main board

Pag.

123

12.2

CONNECTORS LAYOUT

Pag.

123

ALARM MESSAGES AND TROUBLESHOOTING

Pag.

130

13.1

ALARMS THAT STOP THE DISHWASHER

Pag.

130

13.2

13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS
ALARMS THAT DON'T STOP THE DISHWASHER

Pag.
Pag.

130
134

ALARMS THAT DON'T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER

Pag.

136

Pag.

137

13.3
14

LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS

DOC. NO. 5956.65J.00

P. 2 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

1 KEYBOARDS
1.1 HOOD TYPE Style

dEt

Fig. 1 Detergent dispenser Manual
Activation.

rAi

Fig. 2 Rinse Aid Dispenser Manual
Activation

---

Fig. 3 Rinse Pump Manual
Activation (used to EMPTY
BOILER)

SETTING MODES:
To enter into one setting mode (Figure 4),(Figure 5) the appliance should be in stand-by: switch on the appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure
of the two keys.

GEn

Fig. 4 Enter into General
Parameters (Hold down buttons for
at least five seconds).

888

Fig. 6 Next Parameter Family OR
Increase Parameter Value(In setting
mode only)

DOC. NO. 5956.65J.00

FAC

Fig. 5 Enter into Factory
Parameters (Hold down buttons for
at least five seconds)..

888

Fig. 7 Decrease Parameter Value(In
setting mode only)

888

Fig. 8 Confirm Value and go to next
Parameter (In setting mode only).

P. 3 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

1.2 UNDERCOUNTER Style

dEt

TANK
BOILER

Fig. 9 Detergent dispenser Manual
Activation

rAi

TANK
BOILER

Fig. 10 Rinse Aid Dispenser
Manual Activation

---

TANK
BOILER

Fig. 11 Rinse Pump Manual
Activation (used to EMPTY BOILER)

SETTING MODES:
To enter into one setting mode (Figure 12), (Figure 13) the appliance should be in stand-by: switch on the
appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure of the two keys.

GEn

Fig. 12 Enter into General
Parameters (Hold down buttons for
at least five seconds).

FAC

TANK
BOILER

Fig. 13 Enter into Factory
Parameters (Hold down buttons for
at least five seconds).

888

TANK
BOILER

Fig. 14 Next Parameter Family OR
Increase Parameter Value (in setting
mode only)

888

TANK
BOILER

Fig. 15 Decrease Parameter Value
(In setting mode only)

888

DOC. NO. 5956.65J.00

TANK
BOILER

TANK
BOILER

Fig. 16 Confirm Value and go to
next Parameter (in setting mode
only).

P. 4 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

2 MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS
When replacing detergents may be necessary activate the dispensers to fill hoses.

2.1 Detergent Dispenser Activation
Switch on the dishwasher.
Press and hold down CYCLE_2 and CYCLE INFINITE keys, after two
'beep' the detergent dispenser starts work for 20 sec.

dEt

2.2 Rinse Aid Dispenser Activation
Switch on the dishwasher.
Press and hold down CYCLE_1 and CYCLE INFINITE keys, after two
'beep' the rinse aid dispenser starts work for 40 sec.

rAi

3 RINSE PUMP MANUAL ACTIVATION
Use this function to empty the boiler (if the dishwasher is not to be used for a long time, for maintenance operation: ex. before replacing main board).

---

DOC. NO. 5956.65J.00

Switch on the dishwasher.
Close the door and press and hold down DRAIN and CYCLE INFINITE
keys. A buzzer signal indicates the rinse pump activation and the display shows three blinking lines. Three beeps indicate the cycle end.

P. 5 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

4 DETERGENT AND RINSE AID DOSAGE
In this paragraph is explained how to set the working time for the detergent and rinse aid dispensers.
For each dispenser there are two parameters: the initial time and the time during cycle execution.

4.1
Sym.

General Parameters
Parameter Description

Unit

Min

Max

Factory Default

Initial Detergent Dosage (during filling tank)

[s]

0

240

90

Initial Rinse Aid Dosage (starts when tank filled)

[s]

0

180

10

Detergent Dosage During Cycle Execution (during wash
phase)
Rinse Aid Dosage During Cycle Execution (when refilling boiler)

[s]

0

182 (*)

8

[s]

0

62 (*)

4

How change the duration:
o Switch OFF and switch ON the dishwasher;
o Enter into the USER SETTING mode by pressing and hold down ON/OFF and CYCLE_1 keys for at least five seconds the display shows
(Figure 17);
o Press CYCLE_INFINITE. The display shows alternatively the symbol dIn and the duration in seconds (Figure 18) and
(Figure 19) ;
o NOTE: If User Interface v.3.00 tank led is on if value correspond to factory default ( Default 1 - HOOD TYPE).
o Use CYCLE_1 key to decrease the duration and CYCLE_2 key to increase (Figure 19);
o After settled the duration press CYCLE_INFINITE key to store value. The display shows the next parameter
(Figure 20) and the corresponding value (Figure 21);
o In the same way is possible to change the other duration; when finished switch OFF and switch ON.

GEn

Fig. 17 Enter into User Mode (press for 5 sec)..

dIn

Fig. 18 Initial detergent
dosage.

dEt

Fig. 22 Cycle detergent
dosage.

DOC. NO. 5956.65J.00

90

Val.Fabbr.

Fig. 19 Change duration.
(Tank LED indicates default).

8

Val.Fabbr.

Fig. 23 Change time
activation (Tank LED
indicates default)

rIn

Fig. 20 Initial rinse aid
dosage

rAi

Fig. 24 Cycle rinse aid
dosage.

24

Fig. 21 Change duration

7

Fig. 25 Change time
activation.

P. 6 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

(*) Note for external dispensers:
o

if

the detergent dispenser works when WASHING PUMP is being activated; at the
same time voltage is supplied between connectors L17-L19 (main terminal box);

o

if

o

if

o

if

the detergent dispenser works when LOADING EV is being activated to re-fill boiler
level; at the same time voltage is supplied between connectors L17-L19 (main terminal box);
the rinse aid dispenser works when LOADING EV is being activated to re-fill boiler
level; at the same time voltage is supplied between connectors L18-L19 (main terminal box);
the rinse aid dispenser works when WASHING PUMP is being activated; at the
same time voltage is supplied between connectors L18-L19 (main terminal box);

- For electrical connections refer to electric diagram -

Example
Suppose there is connected an external detergent dispenser with a probe into the tank. A typical setting
could be:
the dispenser is not activated during filling tank;
the dispenser is supplied during washing phase and the probe automatically dose the right
detergent amount.

DOC. NO. 5956.65J.00

P. 7 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

5 COUNTERS
This Parameter Family collects cycle counters and water consumption counters.
(calibration parameter) into
For water consumption counters a flow meter must be installed. See
section (8 OTHER PARAMETERS).

5.1
Sym.

Counters
Parameter Description

Unit

Min

Max

Factory
Default

Cycles performed counter.
symbol and two numbers blink consecutively. The cycle number
is obtained by joining the two numbers.

->

Ex.

->

-

means 10042 cycles executed.

Cycle counter (resettable).
This counter is similar to
parameter below).

but is resettable by user (see

-

Water Consumption (only for dishwashers with incorporated continuous
water softener).
Counts m3 of water consumption.
Water Consumption (only for dishwashers with incorporated continuous water softener).
Counts litres of water consumption.
[m3]

The total consumption is given by adding

and

Reset resettable counters:

[l]

[l] values.

Water Consumption: resettable counter. [present up to software version
3.12]
Counts the litres of water and is resettable by user (see
ter below).

[m3]

parame-

[l]

and

To reset put 1 this parameter, switch off and then on again:
will show zero. Note that

and

is used to count cycles for

message (see next parameter,
Store thousand of cycles after that
play.
Ex. If this parameter is settled to 20,

-

).
message appears on dismessage appears when

-

reach 20.000 cycles.
Drain/Cleaning cycles performed.
Similar to

but counts Cleaning Cycles.

-

Numbers of cycles that can be made after a regeneration cycle (only for
dishwashers with non-continuous water softener) [See paragraph 9.1
RESIN REGENERATION CYCLE.].

-

Regeneration cycle counter (only for water softener dishwasher)
[See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER].
only counts efficient regeneration
cycles, i.e. those carried out with salt in the special container (only for
dishwashers with incorporated continuous water softener)

-

Counter of regeneration cycles done without salt in the special container. (only for dishwashers with incorporated continuous water softener) [See paragraph 9.4 DISHWASHER WITH INCORPORATED
CONTINUOUS WATER SOFTENER].

-

DOC. NO. 5956.65J.00

20

P. 8 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

GEn

Fig. 26 USER setting mode
(press for 5s).

CYC

Fig. 29 CYCLES

DOC. NO. 5956.65J.00

GEn

Fig. 27 Next Family

010

Fig. 30 Thousand.

Cnt

Fig. 28 Counters Fam.:
ENTER

042

Fig. 31 Units.

cYc

Fig. 32 Next counter.

P. 9 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank.

6.1
Sym.

Factory Parameters
Unit

45

95

78

2

10

2

[C]

0

98

96

[C]

0

10

1

[min]

0

42

5

0

7

4

-

0

1

1

[C]

0

15

2

[C]

0

20

0

[C]

40

85

63

[C]

2

30

5

[C]

-

Factory
Default

[C]

Heater switch on if boiler temperature is below:

Max

[C]

Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off.
Boiler Temperature HISTERESIS, (represent dead band).

Min

[C]

Parameter Description

0

95

75

[C]

0

10

1

[min]

0

42

20

Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value

alarm appears.

alarm.

Put 0 to disable

Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least
otherwise

C

warning appears.
warning.

Put 0 to disable
Boiler Filling Timeout.

If filling time is longer than

,

alarm appears.

alarm.

Put 0 to disable

Boiler Temperature Adjust.
Boiler Priority (enable boiler wait function)
0=disabled
1=enabled
Booster Function
Overheat gap over Boiler Temperature Threshold
Boiler temperature negative differential: when the dishwasher is in
standby, boiler threshold becomes:
(Used to save energy during machine inactivity by keeping boiler
water at a lower temperature).
Tub Temperature: THRESHOLD
When tank temperature reaches this value, heater switch off.
Tub Temperature: HISTERESIS, (represent dead band).
Heater switch on if tank temperature is below:

-

Tank Temperature: HIGH LIMIT.
When tank temperature reaches this value

alarm appears.

alarm.

Put 0 to disable

Tank Temperature: LOW LIMIT.
During tank warm-up, temperature must increase at least
otherwise

warning appears.

Put 0 to disable

C

warning.

Tank Filling Timeout.
If filling time is longer than
Put 0 to disable

DOC. NO. 5956.65J.00

,

alarm appears.

alarm.

P. 10 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

To modify thresholds do the following:
o Switch OFF and switch ON the dishwasher;
o Enter into the FACTORY SETTING mode by pressing and hold down ON/OFF and CYCLE_2 keys for at
least five seconds (Figure 33);
o Press CYCLE INFINITE. The display shows alternatively the symbol
(Figure 34) and the corresponding value
(Figure 35);
o Use CYCLE_1 key to decrease the value and CYCLE_2 key to increase (Figure 35);
o Press CYCLE INFITE key to confirm. The display shows the next parameter (Figure 36) and the corresponding value (Figure 37);
o In the same way is possible to change the other parameters; when finished switch OFF and switch ON.

FAC

Fig. 33 Factory setting
mode.

2

Fig. 37 Change value &
Store

bt C

Fig. 34 Boiler temp.
threshold

bHi

Fig. 38 Tank temp. High
limit.

76

Fig. 35 Change value &
Store

96

btH

Fig. 36 Boiler Temp
Hysteresis

bLo

Fig. 39 Change value &
Store.

At the end the display will show again
and by pressing CYCLE_2 key (Fig. 41) is possible to change
cycle duration (see paragraph 7 CYCLE SETTING).
).

FAC

Fig. 40 Factory setting
mode

DOC. NO. 5956.65J.00

FAC

Fig. 41 Next Family

Cy1

Fig. 42 Cycle 1 Family:
ENTER.

P. 11 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

7 CYCLE SETTING
IIn this paragraph is explained how to change cycle phases duration (see paragraph 7.1 CYCLE DIAGRAM).
o Switch on the dishwasher;
o Enter into the FACTORY SETTING mode: press and hold down ON/OFF and CYCLE_2 keys for at least 5
seconds (Figure 43);
o Press CYCLE_2 key to select CYCLE_1 parameters.
o Press CYCLE_INFINITE. The display shows alternatively the symbol
(Figure 46) and the corresponding value (Figure 47);
o Use CYCLE_1 key to increase the value and CYCLE_2 key to decrease (Figure 47);
o Press CYCLE_INFINITE key to confirm. The display shows the next parameter (Figure 48) and the corresponding value (Figure 49);
o In the same way is possible to change the other parameters;.

FAC

Fig. 43 Factory setting
mode.

0

Fig. 47 Change value &
Store

FAC

Fig. 44 Select next class.

5h1

Fig. 48 Wash duration [sec].

Cy1

Fig. 45 Cycle 1 Family:
ENTER.

Ln1

Fig. 46 Wash duration [min].

35

Fig. 49 Wash duration
[min]..

After settled all parameters referring Cycle 1, by pressing CYCLE_2 key is possible to change the Cycle 2
parameters (Figure 50), (Figure 51) and so on.

Cy1

Fig. 50 Cycle 1 Parameters.

Cy2

Fig. 51 Cycle 2 Parameters:
ENTER.

Cy2

Fig. 53 Cycle 2 Parameters:
next Family

DOC. NO. 5956.65J.00

Ln2

...

Fig. 52 Wash duration [min].

Cy3

Fig. 54 Cycle 3 Parameters:
ENTER

Ln3

...

Fig. 55 Wash duration [min].

P. 12 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

7.1 CYCLE DIAGRAM
CYCLE TYME

IPA

Ln Sh

PA
Pr

ri

cr

dr

rPA

FP

dEt

rAi

LEGENDA:
= wash
= pre rinse

= drain
= rinse pause
= final pause

= rrinse

= detergent

= cold rinse

= rinse aid

DOC. NO. 5956.65J.00

P. 13 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

7.2

Cycle 1 Parameters
Parameter Description

Unit

Min

Max

Factory
Default

Wash Phase Long

[min]

0

20

0

Wash Phase Short

[s]

1

60

35

Pause

[s]

0

20

4

Pre-rinse Duration

[s]

0

30

0

Rinse Phase Duration

[s]

10

45

16

Cold Rinse Phase Duration

[s]

0

50

0

Drain

Sym.

[s]

0

40

16

Final Pause at End of Cycle

0

60

0

[min]

0

60

0

Short wash time in mode Thermal Label

[s]

0

60

59

Parameter Description

Unit

Min

Max

Factory
Default

Wash Phase Long

[min]

0

20

0

Wash Phase Short

[s]

1

60

45

Pause

[s]

0

20

4

Pre-rinse Duration

[s]

0

30

0

Rinse Phase Duration

[s]

10

45

16

Cold Rinse Phase Duration

[s]

0

50

0

Drain

[s]

0

40

16

Final Pause at End of Cycle

[s]

0

60

0

Long wash time in mode Thermal Label

[min]

0

60

1

Short wash time in mode Thermal Label

[s]

0

60

12

Parameter Description

Unit

Min

Max

Factory
Default

Wash Phase Long

[min]

0

20

1

Wash Phase Short

[s]

1

60

40

Pause

[s]

0

20

4

Pre-rinse Duration

[s]

0

30

0

Rinse Phase Duration

[s]

10

45

16

Cold Rinse Phase Duration

[s]

0

50

0

Drain

[s]

0

40

16

Final Pause at End of Cycle

[s]

0

60

0

Long wash time in mode Thermal Label

[min]

0

60

2

Short wash time in mode Thermal Label

7.3

[s]

Long wash time in mode Thermal Label

[s]

0

60

12

[C]

0

95

0

Cycle 2 Parameters
Sym.

Cycle 3 Parameters

7.4
Sym.

Boiler Temperature Threshold: only for Cycle 3.
This parameter allows having a different rinsing temperature for
the third cycle. Only values above 45C are allowed.

DOC. NO. 5956.65J.00

P. 14 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

7.5

Drain/Cleaning Cycle Parameters
Unit

Min

Max

Factory
Default

Initial Drain Phase Duration

[s]

0

240

40

Final Drain Phase Duration

[s]

0

240

80

Drain without cleaning cycle

-

0

1

0

Number of wash cycles possible between one drain cycle and the
next

[wash
cycles]

0

200

0

Indicates the maximum permissible delay between drain cycle
start and the reaching of a tank level below the work level. If the
set delay is exceeded, alarm B1 occurs.

Sym.

[s] x 10

0

100

18

Parameter Description

8 OTHER PARAMETERS
8.1

Dishwashing Parameters
Sym.

Parameter Description

Min

Initial Pause before start washing (for ALL cycles)

[s]

0

10

0

Delay for the 2nd wash pump (PW only)

[s]

0

10

3

Active a drain phase at the end of washing phase.

[s]

0

40

0

Duration of pause after rinse cycle (valid for dishwashers with
door/hood lock device) [See par. 9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE].

[s]

0

60

0

Celsius/Fahrenheit selection
0 = Celsius
1 = Fahrenheit

-

0

1

0

Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 = during rinse phase the display shows boiler temperature;
1 = during rinse phase the display shows rinse temperature;

-

0

1

0

[p/l]

0

255

0

-

0

5

5

-

0

1

0

Boiler temperature in mode Thermal Label.

[C]

45

97

86

Tank temperature in mode Thermal Label.

[C]

40

90

75

Tank temperature hysteresis in mode Thermal Label.

[C]

0

30

2

Pressure sensor threshold 1 [present up to software version 2.11].

-

0

255

140

Pressure sensor histeresis 1 [present up to software version 2.11].

-

0

255

50

Pressure sensor threshold 2 [present up to software version 2.11].

-

0

255

140

Pressure sensor histeresis 2 [present up to software version 2.11].

-

0

255

50

Pulse Per Litre.
This parameter must be settled in according to flow meter
installed [present up to software version 3.12].
Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor - par. 9.3
DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION)
[
]
Enable mode Thermal Label: if set to 1 it enables the mode and
disables the " endless cycle " button

Max

Factory
Default

Unit

Note:
,
,
,
parameters emulates a two levels pressure switch, keep in mind that value
doesn't correspond to a physical quantity.

DOC. NO. 5956.65J.00

P. 15 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

8.2

Read Only Parameters
Sym.

Parameter Description

Unit

Min

Max

Factory
Default

Main Board Firmware Release

-

-

-

-

Water softener board software version. (only for dishwashers with
incorporated continuous water softener).

-

-

-

-

Active column: indicates through which of the two continuous
water softener columns boiler filling is being carried out: 0 = column A and 1 = column B (only for dishwashers with incorporated
continuous water softener).

-

-

-

-

-

-

-

-

When
alarm appears, the machine is frozen and this
parameter is 3.
After maintenance (see alarm codes document), insert 0 to enable the machine.

-

-

-

-

This alarm appears in case of malfunctioning in the continuous
water softener. To facilitate fault-finding, see par. 13.3 ALARMS
THAT DON'T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER.

-

-

-

-

When

message appears, the parameter value becomes 3.

After maintenance, to clear

8.3

message, insert 0.

Communication and HACCP Parameters
Sym.

Parameter Description

Unit

Min

Max

Factory
Default

Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1)
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is necessary)
9 = Dishwashers with incorporated continuous water softener
16 = HACCP printer (8N1)
32 = MODEM GSM
(DAAS 8N1)
33 = MODEM GSM
(DAAS 8E1)
48 = Hyper Terminal (8N1)

-

0

63

1

Address.
This parameter specifies the address of the appliance into the
'HACCP_network'.
Works only if 'HACCP network' is selected (see above parameter).

-

0

255

1

Print parameter table.

-

0

1

1

[C]

45

95

90

[C]

0

20

10

[C]

35

75

68

[C]

0

20

10

HACCP 'Basic' (printer)
Boiler temperature: high limit.
HACCP 'Basic' (printer)
Boiler temperature: gap below high limit.
HACCP 'Basic' (printer)
Tank temperature: high limit.
HACCP 'Basic' (printer)
Tank temperature: gap below high limit.

DOC. NO. 5956.65J.00

P. 16 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

8.4

Configuration Parameters
Sym.

Parameter Description
Dishwasher Model:
0 = HOOD TYPE & UNDERCOUNTER
1 = POT WASHER
2 = AUTOMATIC POT WASHER
3 = MEDICAL LINE DISHWASHER WITH LOCK DOOR/HOOD
DEVICE
Boiler type:
0 = ATMOSPHERIC BOILER
1 = PRESSURE BOILER

Unit

Min

Max

Factory
Default

-

0

3

0

-

0

2

0

0

3

1

-

0

3

-

-

0

3

0

-

0

2

1

[C]

0

85

75

-

0

1

0

2 = EXTERNAL BOILER
Door type:
0 = AUTOMATIC HOOD
1 = MANUAL HOOD
2 = FRONT LOADING
3 = POT WASHER
Default model (see Default tables):
1 = HOOD TYPE
2 = POT WASHER
3 = UNDERCOUNTER
Solid State Relay (TRIAC).
0 = not enabled;
1 = SOFT START enabled;
3 = SLOW SOFT START enabled
(works only on boards with Solid State Relay).
Boiler/Tank heating swap:
0 = boiler heaters and tank heater can work simultaneously;
1 = swap enabled: tank heating starts only boiler temperature is
reached;
2 = The booster heating elements and the wash pump have priority. The tank heating element is activated only when the booster
has reached the set temperature and the wash pump is not working.
(Note: disabling this function changes the global electrical power
of appliance; before enabling this function check available power,
supply cable section, fuses in according to User Manual).
Tank Filling Mode
Enable filling tank by means of rinsing cycles.
Ex:
= 75 means that boiler water is heated at 75C, then
follows a rinse phase and so on until tank is full.

If
= 0 the tank is filled by solenoid valve in the traditional
way (On machines with incorporated continuous water softener,
even if
is set to 0, filling occurs through subsequent rinses).
Detergent Level Switches
0 = level switches not enabled;
1 = enable detergent level switches;

DOC. NO. 5956.65J.00

P. 17 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

USER INTERFACE MODEL
8 = ACTIVE function disabled (up to version 3.11 [up to serial
nr. 42100099] set to 0)
9 = hood type, under counter (up to version 3.11 [up to serial
nr. 42100099] set to 1)
13 = LS5 with atmospheric boiler(up to version 3.11 [up to
serial nr. 42100099] set to 5)
15 = LS5 with pressure boiler (user interface without display); (up
to version 3.11 [up to serial nr. 42100099] set to 7)
24 = LS5 with atmospheric boiler (From Ser. Nr.: 821).
See parameter
(family
installed in the board.

Sym.

-

0

27

9

) to check the software version

Parameter Description

Unit

Enable "regeneration cycle" key (only for dishwashers with noncontinuous water softener) [See paragraph 9.1 RESIN REGENERATION CYCLE].

Min

Max

Factory
Default

-

0

1

0

-

0

1

1

Air gap with float level sensor normally closed (the level sensor is
closed when the boiler is empty). E.g. the boiler level sensor for
machines with incorporated continuous water softener.

-

0

1

0

Forced start of a resin regeneration cycle (only for dishwashers
with incorporated continuous water softener). [See paragraph 9.4
DISHWASHER WITH INCORPORATED CONTINUOUS WATER
SOFTENER].

-

0

2

0

Max. rinse water hardness (only for dishwashers with incorporated continuous water softener). After modifying, disconnect and
reconnect the machine's main power supply by means of the
main switch. [See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER].

fH

4

14

10

Boiler heating control.
Defines the max. permissible temperature difference during boiler
heating in a time interval of 2 minutes and 30 seconds.

C

25

80

50

Min

Max

0.1 s

0.0 s.

20.0 s

15

0.1 s

0.0 s

20.0 s

200

0.1 s

0.0 s.

20.0 s

15

DELAY_K
Time within which K and K' must be both closed or both open.

0.1 s

0.0 s.

20.0 s

10

DELAY_S3
Time during hood lifting within which the bottom limit switch must
return to the rest position..

0.1 s

0.0 s.

20.0 s

20

ALARMS ENABLE
0 = alarms disabled (to disable also warnings see

and

);
1 = alarms enabled;
If this function is disabled, faults can be detected so display do not
shows any alarm code.

8.5

Parameters for automatic hood type dishwashers
Sym.

Parameter Description
DELAY_K1
Time (during hood lifting) within which S3" must return to the rest
position.
HOOD_TOUT
TIMEOUT - max. time allowed for complete hood opening/closing.
DELAY_K1_S3
During hood lowering, firstly S3" must cut in and then after a time

.the bottom limit switch S3.

DOC. NO. 5956.65J.00

Unit

Factory
Default

P. 18 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

DELAY_S5
Time during hood lowering within which the top limit switch must
return to the rest position.

0.1 s

0.0 s.

20.0 s

20

Displays the last alarm code relative to automatic hood type dishwashers.

-

-

-

0

Parameter only valid for hood type models.
Hood lifting motor absorption threshold.
(50 units correspond to a current of approx. 1 ampere).

-

0

250

100

DOC. NO. 5956.65J.00

P. 19 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

9 SPECIAL FEATURES
9.1 RESIN REGENERATION CYCLE

TANK
BOILER

The regeneration cycle is activated by pressing the button shown in the figure, for at least 5 seconds.
(in family
) must be set to 1.
For this key to be enabled parameter
At this point you can enter the number of wash cycles that can be performed after each regeneration: paramin the counters family
. If
is set to zero the counter is disabled, otherwise after the preeter
set number of cycles the message
is displayed to confirm that regeneration is possible (this is an
information-only message with no effect on operation of the appliance, so you can continue to use the dishwasher). The message is cleared when the regeneration cycle is terminated.
in the
The number of regeneration cycles performed can be checked by consulting the parameter
family of counters.
When there are just 15 cycles remaining before the next regeneration cycle, at the end of the wash cycle the
display shows the message
followed by
, at the end of the next wash cycle the display shows
and
, and so forth, i.e. the display informs the user of the number of wash cycles still available before resin
regeneration is required.
Before starting the regeneration cycle remove the siphon spillway.
WARNING:
If the regeneration cycle is accidentally started, it can be switched off by pressing the button shown in
the figure, for at least 5 seconds
The hardness of the water exiting the softener can vary between 3f - 10 f / 1.7 d - 5.6 d / 2.1 e - 7 e.

9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE
The medical line dishwasher with door/hood lock device has a device that prevents door/hood opening for the
entire duration of the work cycle.
For the door/hood lock to be active, the parameter
(in the
family) must be set to .
The dishwasher door/hood is locked at the start of a wash cycle and is released at the end of the final pause
after rinse. The wash compartment can be accessed by stopping the work cycle in progress, as the locking
device is thus disabled. .
A pause at the end of rinse can be set by means of the parameter
(in the
family). This parameter
is common to all 3 wash cycles. The rinse water temperature is displayed during this pause. Another final
,
,
. During the final pause the display
pause in the cycle can be set by setting the parameters
shows the time remaining for completion of the cycle. The door/hood lock device will be deactivated at the end
,
,
).
of the final pause (
For correct performance of the wash cycle the pause at the end of rinse and the final pause must assume the
default values (see Prog 032 - 034 - 035).

9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION
By setting the parameter
(in the
family) to 1, management of the level sensors located inside the
external detergent and rinse aid tanks is enabled. During the rinse phase, when the rinse aid inside the tank
appears on the display.
has finished, the message
When the detergent inside the tank is finished, the message
is displayed and after a number of wash
cycles equal to
(in the
family) the dishwasher inhibits the activation of other wash cycles. Therefore the detergent level in the tank must be restored.

DOC. NO. 5956.65J.00

P. 20 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER
Dishwashers with incorporated continuous water softener have a continuous softener in the water circuit. By
means of special resins, this device removes the calcareous substances from the feed water, supplying decalcified water for washing.
To activate the continuous water softener, set the parameter
(in the
family) to the value .
For the continuous softener to work properly the resins must be regenerated periodically with a frequency
depending on the hardness of the inlet water, the number of wash cycles carried out and the max. hardness
set with the parameter
(in the
family).
Unlike conventional water softeners, this continuous softener does not require machine stops for regenerating
the resins.
To regenerate the resins it is necessary to put coarse salt in the special container located in the dishwasher.
In particular, the salt container must be filled when the dishwasher is started the first time and whenever the
message
appears on the display and an audible alarm sounds. The salt container holds up to 1.5
kg of salt
WARNING:
Use only coarse salt with a NaCl purity grade of 99.8 %. The use of salt with a lower purity grade may
cause the sale container filter to clog and the water softener to malfunction.

WARNING:
The message
may appear, for several rinse, tank filling or wash cycles, even after replenishing the salt, as the salt must circulate in the entire system. This, however, does not affect correct
dishwasher operation.
The number of regeneration cycles performed can be checked by consulting the parameter
family of counters.

in the

only counts regeneration cycles carried out with the salt container adequately filled; there is another
counter,
(in the
family) that indicates the number of regeneration cycles done without salt.
If the parameter SrU is set to the value10, according to the factory setting, the water softener outlet water
hardness can vary between 3f - 10 f / 1.7 d - 5.6 d / 2.1 e - 7 e.
AUTONOMY OF THE FULL SALT CONTAINER ACCORDING TO THE CHANGE IN INLET WATER HARDNESS
Water hardness
f
15
20
25
30
35
40

d
8,4
11,2
14
16,8
19,6
22,4

e
10,5
14
17,5
21,1
24,6
28,1

The salt container must be fil- Using cycle 2 for 30 cycles/day, the salt
led approximately every (*):
container must be filled approximately
every (*):
Days
Cycles
1168
39
837
28
589
19
506
17
423
14
341
11

(*) Considering a rinse time according to the factory settings.
Maximum outlet water hardness can be modified by setting the
modified from the value of 4 f to 14 f.

value. The outlet water hardness can be

NB: To save the new water hardness value, in addition to the normal parameter modification and saving operations it is necessary to disconnect and reconnect the machine's main power supply by means of the main
switch on the external board.
Water softener operation can be checked by forcing the regeneration of resins, without waiting for the outlet
water hardness to reach the set max. value (
).

DOC. NO. 5956.65J.00

P. 21 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

To do this, wait for the water softener to finish previous resin washing or regeneration operations and set the
parameter
(
family) to for regenerating column A or to for regenerating column B.
Switch the machine off and on again so that it carries out complete regeneration of the set column. If previous
resin washing or regeneration operations were not completed, the manual request for regeneration is not carried out.
It is possible to check which column is being used for boiler filling by querying the parameter
ily): if
= 0 column "A" is used, if
=1 column "B" is used.

(

fam-

The number of litres used by the machine can be checked by querying the parameters
(m3 ) and
(litres). To calculate the total number of litres used by the machine, add the
and values.
NB: In machines with incorporated continuous water softener, tank filling must be done through subsequent
rinses from the boiler and cannot occur by overflow since the filling system does not allow overflow in the tank.
Therefore, even if the parameter
is set to , filling is done by subsequent rinses..

9.5

HOOD-TYPE DISHWASHER WITH CYCLE THERMAL LABEL

WARNING:
Functions present with firmware version 4.04.
If the parameter
(Thermal Label enabled) of
the family
is set to , the " Endless cycle "
button has the " endless cycle " function and the
" high productivity " mode is non-settable.
If the parameter
(Thermal Label enabled) of
the family
is set to , the " Endless cycle "
button does not have the " endless cycle " function
but that of the " high productivity " mode.
This means that the machine can work in 2 modes,
" high productivity " and " Thermal Label " . When the
machine is set in " high productivity " mode, the
parameters which define the cycle times and
temperature set points are the standard
parameters, whereas when the machine is set in
" Thermal Label " mode, the parameters are
dedicated (they are new parameters listed below).
The mode Thermal Label provides for cycle times,
tank hysteresis and tank and boiler temperatures
such as to pass the " Thermal Label " test.
Press and hold down the button to switch the
machine from " high productivity " mode to " Thermal
Label " mode and vice versa.
The " high productivity " button LED is off when the
machine is set in " Thermal Label " mode (factory
default) and lights up when the button is pressed
and the machine is configured in " high productivity "
mode. Whenever the machine is shut down, it
memorises the mode with which is was switched off
and reloads it when switched on the next time.

9.6

New parameters:
o
(family
): if set to
it enables the
Thermal Label mode (and disables the "endless
cycle" button).
o
(family
): temperature set point for the
boiler during the cycles Thermal Label.
o
(family
): temperature set point for the
tank during the cycles Thermal Label.
o
(family
): hysteresis temperature for
the tank during the cycles Thermal Label.
o
(family
): long wash time for cycle 1 in
Thermal Label mode.
o
(family
): short wash time for cycle 1
in Thermal Label mode.
o
(family
): long wash time for cycle 2 in
Thermal Label mode.
o
(family
): short wash time for cycle 2
in Thermal Label mode.
o
(family
): long wash time for cycle 3 in
Thermal Label mode.
o
(family
): short wash time for cycle 3
in Thermal Label mode.

DISHWASHERS WITH WASH TANK WATER CHANGE FREQUENCY CONTROL

WARNING:
Function included starting from firmware version 5.00.

DOC. NO. 5956.65J.00

P. 22 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

If the parameter
(Cycles before drain) of the family
is set to a value higher than , a wash tank
water change frequency control is enabled. The purpose of this function is to display a message telling the
customer when a tank water drain cycle is required. In this way, if the customer does what the machine suggests, washes will be done with sufficiently clean water.
The value set in the parameter
(Cycles before drain) indicates the number of wash cycles possible
between one tank water drain cycle and the next. When the number of wash cycles done since the last tank
water change reaches the value contained in the parameter
(Cycles before drain), the display shows the
message "
" at the start of a wash cycle and the message "
" at the end of the same cycle. When
these messages appear on the display at the start and end of the wash cycle, a tank water drain cycle must
be done to ensure washes with sufficiently clean water.
WARNING:
If the tank drain cycle is not done, the machine does not shut down, but will continue to do wash
cycles, showing the messages
and
at the start and end of the wash cycle
respectively.

9.7

PERISTALTIC TUBE FITTING AND REPLACEMENT INSTRUCTIONS

Described below is the procedure for inserting and removing the tubes from the peristaltic pumps, in case of
tube replacement.
An exploded view of the parts involved in the tube fitting and removal operations is given below.

Tube

Ruoller

Front box

DOC. NO. 5956.65J.00

P. 23 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

STEP 1 - FITTING THE TUBE
1. Position the roller.

2. Insert the tube of the suction part, turning the roller
clockwise.

3. Keep the tube in the seat in the housing and 4. Keep the tube in the seat in the housing and concontinue turning the roller clockwise, being
tinue turning the roller clockwise.
careful not to damage the tube.

5. Turn the roller a full 360.

DOC. NO. 5956.65J.00

6. Make sure to fit the union in the special seat (delivery).

P. 24 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

STEP 2 - REMOVING THE TUBE
1. Position the roller as shown in the figure.

2. Lift the tube at the suction part and turn the roller at
the same time. Guide the tube, keeping it raised,
and turn the roller.

3. Remove the tube.

DOC. NO. 5956.65J.00

P. 25 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

10 MAIN BOARD CONFIGURATION
When receiving an electronic board (spare part) may be necessary to configure it in according to the machine
where has to be replaced
4. With the machine CODE enter into the following table and read the corresponding Prog. number
5. Follow the instructions reported into the corresponding Prog.XXX sheet (next pages).
6. With the machine CODE find the Layout number in Par. 12.2 CONNECTORS LAYOUT.

10.1 CODE - & gt; Prog. TABLE
MODEL
NUC3DD

CODE
400041

Prog.
103

Layout

MODEL

CODE

Prog.

Layout

16

EUCAI

502025

106

8

502026

106

8

EUC1

400055

101

11

EUCAIDP

EUC1DP

400056

101

11

EUCAI60

502027

106

8

EUC1WS

400057

102

21

EUCAIWS

502028

107

8

21

EUCAIG

502033

106

8

16

EUCAIWSG

502034

107

8

502035

108

8

EUC1DPWS
EUC3

400058
400059

102
103

EUC3WS

400060

104

17

EUCAIML

EUC3DP

400061

103

16

EUCAIMLWS

502036

109

8

EUC3DPWS

400062

104

17

EUCAIMLG

502037

110

10

EUC1G

400063

105

11

EUCAICL

502038

111

18

11

EUCAICLG

502039

111

18

16

EUCAIWL

502040

112

8

EUC1DP60
EUC3DD

400064
400065

101
103

ZUCADDROW

400066

134

16

EUCAICLW

502042

113

18

ZUCADDROW6

400067

134

16

EUCI

502043

114

16

EUCADD60

400068

143

16

EUCIM

502044

115

19

16

EUCIM60

502045

115

19

11

EUCAIDPNW

502046

106

8

FUCA3DD
NUC1DPP

400116
400120

135
101

NUC1DUK

400122

101

11

ZUCI

502047

114

16

NUC1DDUK

400123

101

11

ZUCID

502048

114

16

KUC3

400127

103

16

ZUCAI

502049

106

8

16

ZUCAIDP

502050

106

8

11

ZUCAIDPWS

502051

107

8

502052

106

8

KUC3DP
NUC1DDRUKP

400128
400130

103
146

NUC1GRUK

400131

136

16

ZUCAIG

NUC1

400133

101

11

ZUCAIDDWS

502053

107

8

NUC1DD

400134

101

11

ZUCAID

502054

106

8

11

ZUCAI60

502055

106

8

11

EUCAIUSPH6

502056

125

9

502057

106

8

EUCAIDP
NUC1GMS

400137
400138

128
137

EUC3DPCAG

400139

138

16

ZUCAIDD

NUC1

400140

101

11

EUCAIDD

502058

106

8

NUC1DP

400141

101

11

EUCAIDPJ

502059

106

8

NUC1WS

400142

102

21

EUCAIDPJ60

502060

106

8

502123

145

16

NUC1WSDP

400143

102

21

EUCIDDC

NUC3

400144

103

16

ZUCIDC

502124

145

16

NUC3WS

400145

104

17

EHTA

504226

120

1

NUC3DP

400146

103

16

EHTA60

504227

120

1

NUC3DPWS

400147

104

17

EHTAWS

504228

121

4

17

EHTAI

504229

120

1

11

EHTAID

504230

120

4

504231

121

4

NUC3DDWS
NUC1DP60

400148
400149

104
101

NUC1DPA

400150

105

11

EHTAIWS

ZUCA1

400151

128

11

EHTAIDWS

504232

121

4

ZUCA3

400152

128

16

EHTAIG

504233

120

4

16

EHTAIWSG

504234

121

4

504235

122

15

EUCADDROW

400153

134

EUCADDROW6

400154

134

16

EHTAIAU

NUC1DPDD

400155

101

11

EHTAIMLAU

504236

123

4

NUCAIG

502010

106

8

ZHTAWS

504237

121

4

NUCAIWSG

502011

107

8

ZHTAID

504238

120

4

ZHTAIWS

504239

121

4

DOC. NO. 5956.65J.00

P. 26 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

MODEL

CODE

Prog.

ZHTAIAU

504240

122

ZHTA

504241

120

ZHTA60

504242

ZHTAI

Layout

MODEL

CODE

Prog.

Layout

15

AUCI

698091

114

16

4

AUCAI

698092

116

8

120

4

AUCAIDP

698093

116

8

504243

120

4

AUCAIDPWS

698094

117

8

EHTAIUSPH5

504244

126

2

AUCAIG

698095

106

8

EHTAIUSPH6

504245

126

2

AUCAIWSG

698096

107

8

EHTAO

505036

124

23

ET12AI

698097

129

4

EHT

505046

118

13

ET12AIT

698098

130

4

EHT60

505047

118

13

NHTAG

698110

119

23

EHTAG

505048

119

23

AHTAWS

698115

121

4

EHTM

505049

118

13

AHTAIWS

698116

121

4

EHTM60

505050

118

13

AHTAIG

698117

120

4

NHT

505051

118

13

AHTAIWSG

698118

121

4

NHTD

505052

118

13

AHTA

698119

120

4

NHT60

505053

118

13

AHTAI

698120

120

4

EHTAROW

505054

124

23

S49JGF

103

16

EHTAROW60

505055

124

23

S49LBN

103

16

ZHTAROW

505056

124

23

S49QL1

103

16

ZHTAROW60

505057

124

23

EHTAJ

505058

120

23

EHTAJ60

505059

120

23

EHTAO60

505060

124

23

ZHTAO

505061

124

23

ZHTAO60

505062

124

23

KHT

505063

118

13

NHTM

505064

118

13

NHTM60

505065

118

13

NHTP

505082

118

13

ZHT7

505087

144

23

ZHT76

505088

144

23

EPPWESG

506048

139

4

EPPWESG60

506049

141

4

EPPWEHG

506050

139

4

ZPPWESG

506051

139

4

ZPPWEHG

506052

139

4

ZPPWSSG

506053

139

4

EPPWELG

506054

140

4

EPPWELG60

506055

142

4

ZPPWELG

506056

140

4

ZPPWSLG

506057

140

4

NPPWESG

511326

139

4

NPPWEHG

511328

139

4

NPPWELG

511329

140

4

NUC1G

690028

105

11

NUCA1DDG

698005

136

16

OHTAROW

698047

127

23

OHTAROW60

698048

127

23

NUCA1DPDDG

698049

136

16

NHTDPDDG

698058

119

23

APPWELG

698083

140

4

APPWESG

698085

139

4

APPWEHG

698086

139

4

ET5AIIT

698087

131

8

ET5AIDP

698088

132

8

ET5AIDPWS

698089

133

8

DOC. NO. 5956.65J.00

P. 27 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

10.2 PROGRAMMING SHEETS

NUC1 / EUC1

PROG 101

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 28 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1 / EUC1

PROG 101

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 29 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1WS / EUC1WS

PROG 102

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle enabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 30 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1WS / EUC1WS

PROG 102

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 31 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3 / KUC3 / EUC3

PROG 103

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 32 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3 / KUC3 / EUC3

PROG 103

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 33 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3WS / EUC3WS

PROG 104

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle enabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 34 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3WS / EUC3WS

PROG 104

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 35 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1G / EUC1G

PROG 105

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 36 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1G / EUC1G

PROG 105

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 37 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCAI / AUCAIG / EUCAI /
NUCAI

PROG 106

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled.
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 38 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCAI / AUCAIG / EUCAI /
NUCAI

PROG 106

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 39 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCAI / AUCAI / EUCAI /
NUCAI WS

PROG 107

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 40 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCAI / AUCAI / EUCAI /
NUCAI WS

PROG 107

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 41 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIML

PROG 108

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 42 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIML

PROG 108

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 43 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIMLWS

PROG 109

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 44 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIMLWS

PROG 109

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 45 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIMLG

PROG 110

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Medical line dishwasher with lock door/hood device.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 46 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIMLG

PROG 110

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 47 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAICL

PROG 111

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 48 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAICL

PROG 111

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 49 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIWL

PROG 112

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 50 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIWL

PROG 112

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 51 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAICLW

PROG 113

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 52 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAICLW

PROG 113

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 53 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCI / AUCI / EUCI

PROG 114

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 54 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCI / AUCI / EUCI

PROG 114

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 55 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCIM

PROG 115

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 56 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCIM

PROG 115

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 57 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

AUCAI

PROG 116

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 58 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

AUCAI

PROG 116

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 59 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

AUCAIDPWS

PROG 117

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 60 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

AUCAIDPWS

PROG 117

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 61 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NHT / KHT / EHT

PROG 118

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible)..
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 62 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NHT / KHT / EHT

PROG 118

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 63 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NHTG / EHTG

PROG 119

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 64 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NHTG / EHTG

PROG 119

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 65 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTA / AHTA / EHTA

PROG 120

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 66 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTA / AHTA / EHTA

PROG 120

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 67 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAWS/ AHTAWS/ EHTAWS

PROG 121

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 68 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAWS/ AHTAWS/ EHTAWS

PROG 121

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 69 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAIAU / EHTAIAU

PROG 122

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Automatic Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 70 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAIAU / EHTAIAU

PROG 122

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 71 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EHTAIMLAU

PROG 123

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Automatic Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 72 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EHTAIMLAU

PROG 123

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 73 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAROW / EHTAROW /
ZHTAO / EHTAO

PROG 124

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tank Temperature: Threshold.
Disable tank high Temperature alarm (

).

5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].

DOC. NO. 5956.65J.00

P. 74 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHTAROW / EHTAROW /
ZHTAO / EHTAO

PROG 124

Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Boiler Temperature Threshold for Cycle 3.
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode enabled.
Boiler Temperature in Termal Label mode.
Tank Temperature in Termal Label mode.
Tank Temperature histeresis in Termal Label mode.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 75 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIUSPH

PROG 125

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 76 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCAIUSPH

PROG 125

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees display Fahrenheit.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 77 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EHTAIUSPH

PROG 126

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 78 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EHTAIUSPH

PROG 126

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees display Fahrenheit.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 79 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

OHTAROW / OHTAROW60

PROG 127

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Disabled (for this appliance SOFT START is NOT possible).
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tank Temperature: Threshold.
Disable tank high Temperature alarm (

).

5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].

DOC. NO. 5956.65J.00

P. 80 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

OHTAROW / OHTAROW60

PROG 127

Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode enabled.
Boiler Temperature in Termal Label mode.
Tank Temperature in Termal Label mode.
Tank Temperature histeresis in Termal Label mode.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 81 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCA

PROG 128

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 82 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCA

PROG 128
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.

6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 83 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET12AI

PROG 129

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
SOFT START enabled.
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 84 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET12AI

PROG 129

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 85 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET12AIT

PROG 130

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 86 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET12AIT

PROG 130

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 87 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIIT

PROG 131

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled.
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 88 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIIT

PROG 131

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 89 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIDP

PROG 132

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled.
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 90 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIDP

PROG 132

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 91 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIDPWS

PROG 133

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled.
Alarms enabled.
Boiler float level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 92 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ET5AIDPWS

PROG 133

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Dishwasher with incorporated continuous water softener.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when WASH PUMP in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 93 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCADDROW / EUCADDROW

PROG 134

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tub Temperature: HISTERESIS.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 94 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCADDROW / EUCADDROW

PROG 134

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 95 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

FUCA3DD

PROG 135

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 96 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

FUCA3DD

PROG 135

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 97 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUCA1DDG / NUC1GRUK

PROG 136

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 98 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUCA1DDG / NUC1GRUK

PROG 136

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 99 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1GMS

PROG 137

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 100 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1GMS

PROG 137

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 101 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3 / KUC3 / EUC3

PROG 138

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 102 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC3 / KUC3 / EUC3

PROG 138

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Number of wash cycles possible between one drain cycle and the next.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 103 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZPPW / APPW / EPPW (EX PW1 / PW1H) PROG 139
1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Pot Washer.
Atmospheric boiler.
Front loading function.
Default values for Pot Washer models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 104 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZPPW / APPW / EPPW (EX PW1 / PW1H) PROG 139
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Drain cycle Timeout.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 105 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZPPW / APPW / EPPW (EX PW2)

PROG 140

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Pot Washer.
Atmospheric boiler.
Front loading function.
Default values for Pot Washer models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 106 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZPPW / APPW / EPPW (EX PW2)

PROG 140

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Drain cycle Timeout.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 107 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EPPWESG60 (EX PW1 - 60Hz)

PROG 141

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Pot Washer.
Atmospheric boiler.
Front loading function.
Default values for Pot Washer models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 108 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EPPWESG60 (EX PW1 - 60Hz)

PROG 141

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Drain cycle Timeout.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 109 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EPPWELG60 (EX PW2 - 60Hz)

PROG 142

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Pot Washer.
Atmospheric boiler.
Front loading function.
Default values for Pot Washer models.
Disabled (for this appliance SOFT START is NOT possible).
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 110 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EPPWELG60 (EX PW2 - 60Hz)

PROG 142

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Drain cycle Timeout.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled (Functions present with firmware version 4.04).
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 111 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCADD60

PROG 143

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tub Temperature: HISTERESIS.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].

DOC. NO. 5956.65J.00

P. 112 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

EUCADD60

PROG 143

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 113 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHT7 / ZHT76

PROG 144

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Atmospheric boiler.
Manual Hood.
Default values for Hood Type models.
Enabled.
Boiler heaters and tank heater work simultaneously.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface hood type/ undercounter model.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Disable boiler high Temperature alarm (

).

Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tank Temperature: Threshold.
Disable tank high Temperature alarm (

).

5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].

DOC. NO. 5956.65J.00

P. 114 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZHT7 / ZHT76

PROG 144

Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Long Wash Phase inTermal Label mode [min].
Short Wash Phase inTermal Label mode [s].
Boiler Temperature Threshold for Cycle 3.
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Termal Label mode disabled.
Boiler Temperature in Termal Label mode.
Tank Temperature in Termal Label mode.
Tank Temperature histeresis in Termal Label mode.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 115 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

ZUCIDC / EUCIDDC

PROG 145

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
SOFT START enabled.
Tank heater works only if boiler temperature reached.
The tank is filled into the traditional way.
Detergent level switches not enabled.
ACTIVE function disabled.
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
Alarms enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Cold Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Cold Rinse Phase Duration [s].
Drain [s].
Final Pause [s].

DOC. NO. 5956.65J.00

P. 116 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Cold Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.
Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispensing during the wash cycle (loading during wash stage).
Rinse aid dispensing during the rinse cycle (loading during boiler filling stage).
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

DOC. NO. 5956.65J.00

P. 117 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1DDRUKP

PROG 146

1. Switch OFF and then switch ON the machine.
2.

Enter into CFG parameter family and set the following parameters:
Hood Type and undercounter.
Pressure boiler.
Front loading function.
Default values for Undercounter models.
Disabled (for this appliance SOFT START is NOT possible).
During operation the priorities are booster heating element and wash pump, then tank heating
element. Setting to 0 or 1 is prohibited.
The tank is filled into the traditional way.
Detergent level switches not enabled.
Select user interface for LS5.
Regeneration cycle disabled.
Alarms not enabled.
Boiler electronic level sensor.
Resin regeneration cycle forcing.
Rinse water max. hardness.
Boiler heating control.

3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family and set the following parameters.
Boiler Temperature Threshold.
Boiler temperature: alarm threshold.
Boiler Temperature Adjust.
Boiler standby function enabled.
Booster Function.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tub Temperature: Threshold.
Tank temperature: alarm threshold.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 2 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Cycle 3 parameters family.
Long Wash Phase [min].
Short Wash Phase [s].
Pause [s].
Rinse Phase Duration [s].
Drain [s].
Final Pause [s].
Boiler Temperature Threshold for Cycle 3.

DOC. NO. 5956.65J.00

P. 118 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

NUC1DDRUKP

PROG 146

Drain parameters family.
Initial Drain Phase Duration [s].
Final Drain Phase Duration [s].
Drain and cleaning mode.
Wash tank water change frequency control disabled.
Set other parameters.
Initial Pause [s] (for ALL cycles).
Delay for the 2nd wash pump [s].
Drain Phase Duration at the end of washing phase [s].
Duration of pause after the rinse cycle [s] (for ALL cycles).
Degrees Celsius display.
During the rinse stage, the display shows the boiler temperature.
Enter into HCP parameter family and set the following parameters.
Machine arranged for remote connection to PC.
6. Switch OFF and then switch ON the machine.
Enter into GEn parameter family.
Initial Detergent Dosage.
Initial Rinse Aid Dosage.
Detergent dispenser works when LOAD SOLENOID VALVE in activated.
Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.
7. Switch OFF and then switch ON the machine.

WARNING:
To set the board parameters , carefully follow the order given in this programming file, from point 1 to
point 7.

WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.

WARNING:
Per limitare l'assorbimento massimo a 13A (l'apparecchiatura ? monofase con spina 13A UK), non
devono funzionare contemporaneamente:
- la resistenza della vasca e la pompa di lavaggio,
- la resistenza boiler e la resistenza della vasca.

DOC. NO. 5956.65J.00

P. 119 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

11 DEFAULT VALUES

Default 1 - HOOD TYPE
ON/OFF +
CYCLE1
keys

ON/OFF +
CYCLE2
keys

?

?
->

?

DOC. NO. 5956.65J.00

->
?

?

->
?

->
?

->
?

->
?

->
?

->
?

->
?

?

?

P. 120 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Default 2 - POT WASHER
ON/OFF +
CYCLE1
keys

ON/OFF +
CYCLE2
keys

?

?
->

?

DOC. NO. 5956.65J.00

->
?

?

->
?

->
?

->
?

->
?

->
?

->
?

->
?

?

?

P. 121 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Default 3 - UNDERCOUNTER
ON/OFF +
CYCLE1
keys

ON/OFF +
CYCLE2
keys

?

?
->

?

DOC. NO. 5956.65J.00

->
?

?

->
?

->
?

->
?

->
?

->
?

->
?

->
?

?

?

P. 122 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

12 USER INTERFACE AND MAIN BOARD CONNECTORS
12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD
The display shows

with door/hood closed

No cycle starts
A cycle fails to start
After replacing the main board only the 3rd cycle starts
Cycle time longer than that foreseen
Noisy wash pump (only on HT and PP versions)

Check door/hood micro/sensor
Check the user interface buttons (have they remained
pressed? etc.)
Is a user interface button extension missing?
The main board is still configured for LS5/WT4.
Does the boiler work?
Is the feed water at 50C?
Check the current for single phase during operation.

12.2 CONNECTORS LAYOUT

LAYOUT 1

KEY
CN1
CN2
CN3
CN5
CN8
CN12
CN15
CN16

ZHTA / AHTA / EHTA

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
Detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Energy peak controller input
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.65J.00

P. 123 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 4 ZHTA / AHTA / EHTA / ZHTAWS / AHTAWS / EHTAWS
ZPPW / APPW / EPPW (NO AUT)

ONLY
WS

LAYOUT 8

NUC / EUC / NUCWS / EUCWS / NUCI / EUCI / NUCIWS / EUCIWS

ONLY
WS

KEY
CN1
CN2
CN3
CN5
CN7
CN8
CN10
CN11
CN12
CN15
CN16

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
ECOTEMP transformer, detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Hand safety system microswitch input
Energy peak controller input
Safety and upper/lower limit switch input
Hand safety system input - Gear motor current control input - Gear motor polarity inversion connection
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.65J.00

P. 124 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 10

EUCIM / EUCAIMLG

LAYOUT 11

NUC1 / EUC1 / ZUCA1

ATM

(ZUCA1)

KEY
CN1
CN2
CN3
CN5
CN8
CN11
CN12
CN15
CN16
CN17

PRES

(NUC1 / EUC1)

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
Detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Energy peak controller input
Door lock electromagnet output
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input
Door microswitch connector

DOC. NO. 5956.65J.00

P. 125 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 13

LAYOUT 15

KEY
CN1
CN2
CN3
CN5
CN8
CN11
CN12
CN15
CN16

NHT / EHT / KHT

ZHTAAU / EHTAAU

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
ECOTEMP transformer, detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Energy peak controller input
Hood lock electromagnet output
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.65J.00

P. 126 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 16

NUC / EUC / ZUCI / AUCI /EUCI / ZUCA3 / FUCA3DD / NUCA1DDG / KUC / ZUCADDROW / EUCADDROW

ATM

PRES

(NUC / EUC /
(ZUCA3 /
ZUCI / AUCI /
FUCA3DD /
NUCA1DDG / EUCI / KUC)
ZUCADDROW /
EUCADDROW)

LAYOUT 17

KEY
CN1
CN2
CN3
CN5
CN8
CN9
CN11
CN12
CN15
CN16
CN17

NUCWS / EUCWS

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
Detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Energy peak controller input
Salt receptacle drain pump and low pressure solenoid valve outputs
Brine solenoid valve output
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input
Door microswitch connection

DOC. NO. 5956.65J.00

P. 127 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 18

LAYOUT 19

KEY
CN1
CN2
CN3
CN5
CN7
CN8
CN12
CN15
CN16
CN17

EUCAICL

EUCIM / EUCIM60

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
Detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Detergent/rinse aid level sensors input
Energy peak controller input
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input
Door microswitch connection

DOC. NO. 5956.65J.00

P. 128 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

LAYOUT 21

LAYOUT 23

KEY
CN1
CN2
CN3
CN5
CN8
CN9
CN11
CN12
CN15
CN16
CN17

NUC1WS / EUC1WS

NHTG / EHTG / ZHTAROW / EHTAROW / ZHTAO / EHTAO

Rinse pump/wash pump/solenoid valve outputs
Pressure/atmospheric dishwasher solenoid valve connection
Detergent/rinse aid dispenser and drain pump outputs
Tank/boiler temperature sensor inputs
Energy peak controller input
Salt receptacle drain pump and low pressure solenoid valve outputs
Brine solenoid valve output
User interface inputs/outputs
Overflow/tank level/board feed input
User interface inputs/outputs and hood/door sensor input
Door microswitch connection

DOC. NO. 5956.65J.00

P. 129 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

13 ALARM MESSAGES AND TROUBLESHOOTING
13.1 ALARMS THAT STOP THE DISHWASHER

Want of water
Is the water cock open?
Does the water load solenoid valve work?
Is the water feed flow a min. of 5 l/min?
Is the water inlet filter clean?
Is the load solenoid valve filter clean?
Is the overflow inserted?
Is the main board (ATM-PRES) CN2 connector correctly positioned?
Do the tank/boiler pressure switches work properly?

Rinsing is not done regularly for 2 consecutive cycles
Are the rinse arms clogged?
Does the rinse pump work correctly?
Is there water in the level sensor tube?
Is there scale in the boiler?
Does the boiler level sensor work properly?

ONLY FOR MACHINES WITH CONTINUOUS WATER SOFTENER:
Does the boiler level sensor located inside the water softener work properly?
Does the float of the boiler level sensor, located inside the water softener, work properly? Is it free
to move upwards and downwards and vice versa?
Is the connection from the boiler level sensor to the main board efficient?
ATTENZIONE: RESETTING THIS ALARM WITHOUT FIRST ELIMINATING THE CAUSE IS
DANGEROUS; THE BOILER HEATING ELEMENTS COULD WORK DRY, FURTHER DAMAGING THE INTERNAL PARTS OF THE DISHWASHER.
ATTENZIONE:
IT MUST BE MANUALLY RESET AFTER ELIMINATING THE CAUSE OF
THE MALFUNCTION.

Automatic hood out of order
See par. 13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS.

13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS
When the alarm
appears, to facilitate fault-finding another parameter providing a more detailed indication
has been introduced.
and is found in the
family.
The parameter is
The possible cause of the anomaly can be found (see table below) ?according to the value of the parameter
.
With pot washers the cause that generated a
E.g.: With an automatic hood type the alarm
Access the parameter

in the

type alarm can also be found.
appears.

family.

the top limit switch could be disconnected or interrupted.

DOC. NO. 5956.65J.00

P. 130 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Hood

Pot Washer
S5'

S5

S3: FC_DW

(hood CLOSE)

S5: FC_UP

(hood OPEN)

S4''
S4'''

S3''

S4'
S4

S3

S3'

S1: DOOR_CLOSE

Appears with hood closed if the top limit switch
(FC_UP) cuts in.

During lifting, the bottom limit switch (FC_DW) has
not returned to the rest position.
The limit switch must return to the rest position
:
within a time given by the parameter
a) check that the motor works.

Appears with hood closed, if:
- the bottom limit switch (S3) returns to the rest
position;
- the top limit switch (S5) cuts in;
- S3'' does not cut in.

During the initial lifting phase the bottom limit
switch (S3) must return to the rest position
?
within a time given by the parameter
otherwise the alarm
appears.
- S3 could be stuck.
- S5' could be disconnected.
On installation this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board

Appears if during lifting S3'' does not return to
.
the rest position within a time

Appears if the bottom limit switch (FC_DW) cuts in
during lifting.
(Polarity/motor rotation direction inverted?!).

Appears if the bottom limit switch (S3) cuts in
during lifting.
On installation this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.

DOC. NO. 5956.65J.00

P. 131 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

TIMEOUT-The time taken for hood lifting was
more than the time fixed by parameter
:

TIMEOUT- IThe time taken for lifting was more
than the time fixed by parameter
.

a) check that the motor works.

Check correct operation of the:
a) motor (thermal protection N7);
b) top limit switch (S5 and S5').

The hood is open but the bottom limit switch
(FC_DW) has cut in.

Appears with hood fully open, if:
- the limit switch (S5) returns to the rest position;
- the bottom limit switch (S3) cuts in;
- S3'' cuts in.

Appears if with hood fully open the " door closed "
microswitch cuts in.

During lowering, the top limit switch (FC_UP) has
not returned to the rest position.
The limit switch must return to the rest position
:
within a time given by parameter
a) check that the motor works;
b) (Polarity/motor rotation direction inverted?!)..

Appears if with hood fully open the " door
closed " microswitch cuts in.
- S5 could be disconnected.

During the initial lowering phase the top limit
switch (S5) must return to the rest position
othwithin a time given by the parameter
erwise the alarm

appears.

- S5 could be stuck.
- S3' could be disconnected.
On installation, this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.
-

Appears if the top limit switch (FC_UP) cuts in during lowering.
(Polarity/motor rotation direction inverted?!).

Appears if the bottom limit switch S3 cuts in
before S3 " during lowering.

Appears if the top limit switch (S5) cuts in during lowering.
On installation, this alarm can occur due to
incorrect sequence of the phases: invert the two
phases on the power supply terminal board.

TIMEOUT- The time taken for hood closing was
:
more than the time fixed by parameter

TIMEOUT- The time taken for lowering was
.
more than the time fixed by parameter

a) check that the motor works.

- S3' could be disconnected.

Appears during hood lowering if, after S3'' cuts
in, the bottom limit switch S3 does not cut in
within the time fixed by parameter
.

DOC. NO. 5956.65J.00

P. 132 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

-

The two hand safety contacts K and K' must be
both closed or both open. If this does not occur
the alarm appears.
- One of the two relays (K or K') could be stuck
)
or disconnected. (See parameter

Limit switch combination not allowed:
top limit switch (FC_UP) and bottom limit switch
(FC_DW) activated at the same time!

Limit switch combination not allowed.
Appears if one of the following combinations occurs:
- top limit switch (S5) and bottom limit switch
(S3) both activated (S3 and S5 could be disconnected);
- top limit switch S5 and S3'' both cut in;
- bottom limit switch (S3) cut in but not S3''.
-

During lifting, the current absorbed by the lifting
motor has exceeded the threshold (see parameter

):
a) excessive mechanical force during lifting..
During lowering, the current absorbed by the lifting
motor has exceeded the threshold (see parameter

):
excessive mechanical force during lowering.
The hood should be stopped but the card detects
a high current absorption by the lifting motor:
the relay RL18/RL19 could be stuck;
feeder connector CN32 could be disconnected.

DOC. NO. 5956.65J.00

P. 133 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

13.2 ALARMS THAT DON'T STOP THE DISHWASHER
(SHOWN ON THE USER INTERFACE AT REGULAR INTERVALS)
WARNING:

Alarms marked with the ? symbol from Serial Number 821 have become alarms
which do not lock the machine.

Drain not efficient
Has the overflow been removed?
Is the water drain blocked?
Is the drain pump blocked?
Are the air trap and tank pressure switch clean?
Is there a constriction in the drain tube?
Is the pump breather pipe returning to the tank clogged or constricted?
Does the tank pressure switch work properly?
Is there a hole in the drain tube (only for versions with drain pump)?

Overflow alarm
Is the water drain blocked?
Are the air trap and tank pressure switch clean?
Does the tank pressure switch work properly?
Is the load solenoid valve blocked? (E1 - LOAD_EV)
Is the load solenoid valve relay stuck? (RL8 - LOAD_EV)

?

Boiler temperature rise too fast
Does the boiler level sensor work properly? The boiler could be empty.
Are non-original power resistances installed?

?

Boiler temperature too high
Has the boiler temperature been changed (
Has the software alarm value been modified (

- increased above 90C)?
)?

Does the boiler level sensor work properly?
Is the boiler relay stuck (see RL2, RL3, RL4)?

?

Tank temperature too high
Is the feed water above 60C?
Has the software alarm value been modified (

)?

Is the rinse water temperature too high?
Is the tank relay stuck (RL5 - TUB_HEAT)?

?

Tank temperature sensor out of order
Is the temperature sensor broken or disconnected (NT1)?
Is the temperature sensor connector correctly inserted?

?

Tank temperature sensor out of order
Is the temperature sensor short-circuited (NT1)?

DOC. NO. 5956.65J.00

P. 134 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Boiler temperature sensor out of order

?

Is the temperature sensor broken or disconnected (NT2)?
Is the temperature sensor connector correctly inserted?

Boiler temperature sensor out of order

?

Is the temperature sensor short-circuited (NT2)?

Rinse temperature sensor out of order

?

(only on machines with temperature sensor on the rinse circuit)
Is the temperature sensor broken or disconnected?
Is the temperature sensor connector correctly inserted?

Rinse temperature sensor out of order

?

(only on machines with temperature sensor on the rinse circuit)
Is the temperature sensor short-circuited?

WARNING:
Alarms

,

and

lock the boiler temperature control.

Alarms

,

and

lock the tank temperature control.

In the case of alarms
and
, the boiler waiting phase is not executed (the rinse may be performed
with cold water) and, during the initial warm-up and subsequent rinses (
& gt;
), the boiler heating
phase is not executed.
In the case of an open probe error (
In the case of a shorted probe error (

,

e
,

), the displayed temperature is 10C
e

) , the displayed temperature is 99C.

Communication error
Is the connection between main board and control panel correct? Are the connectors correctly
connected?
Are connector contacts clean?

Tank temperature low
Does the tank heating element work properly?
Are the connectors correctly connected?
Are the dishwasher feed voltage and current correct?
Is the relay RL5 on the board disconnected or faulty?

Boiler temperature low
Does/do the boiler heating element/s work properly?
Are the connectors correctly connected?
Does the possible remote control switch connected to the heating element work correctly?
Is there power at the remote control switch input terminals?
Does relay RL2 on the board work properly?
CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL2 AND THE BOILER HEATING ELEMENTS ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES NOT
HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR TO
ONE OF THE TWO FREE POSITIONS ON THE BOARD.
CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE
OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE,
ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS
ALSO OCCURS WHEN A PHASE IS MISSING.

DOC. NO. 5956.65J.00

P. 135 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

13.3 ALARMS THAT DON'T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER
If alarm
or
appears, the machine indicates it on the display at regular intervals and auto-configures itself in the same way as a machine without water softener. Resin regeneration cycles are not performed and the column used for filling is always the same (column B).
is reset when the machine is switched off and on from the mains switch (only if the causes that
Alarm
generated it have been eliminated).
Alarm
is reset when the machine is switched off and on from the user interface or from the main switch
(only if the causes that generated it have been eliminated).
WARNING:

Alarms marked with the ? symbol from Serial Number 821 have become alarms
which do not lock the machine.

?

Water softener operation errors
This alarm appears in case of malfunctioning in the continuous water softener.
it is necessary to disconnect and reconnect the main power supply to
To reset error
the machine by means of the main switch on the external power board.

?

Communication errors between the mother board and softener board
This alarm appears in case of problems in communication between the mother board and water
softener board; check the connection between mother board connector J1 and water softener
connector ST8

To facilitate the finding of faults signalled by alarm
possible cause of malfunction has been introduced in the

, another parameter providing a more detailed indication of the
family (see table below).

To reset error
it is necessary to disconnect and reconnect the main power supply to the machine by means
of the main switch on the external power board.

Water softener conductivity sensor short-circuit
Two or more water softener conductivity sensors are short-circuited. Check the connections
between the water softener board and sensors, replacing the connection wiring if necessary.

Water softener conductivity sensors open
One or more water softener conductivity sensors are disconnected. Check the connections
between the water softener board and sensors, replacing the connection wiring if necessary.

Resin temperature sensor malfunction
Replace the water softener electronic board.

DOC. NO. 5956.65J.00

P. 136 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

Water softener electronic board malfunction
Replace the water softener electronic board.

Salt water filling malfunction
The salt water container in the water softener was not completely filled within the
set max. filling time.
Make sure:
- the water cock is open
- the water filling solenoid valve works correctly
- the salt container solenoid valve works correctly
(
up to
- the feed water pressure is at least 50 kPa / 0.5 bar
version 4.01)
- the water inlet filter is clean
- the filling solenoid valve filter is clean
- the salt container cap is properly closed
- the mother board (ATM-PRES) connector CN2 is correctly positioned
- the water softener board connector ST5 is correctly positioned
- the grille on the bottom of the salt container is clogged with dirt.

Inefficient resin washing
After carrying out the maximum permissible number of resin washes, the resins are not sufficiently cleaned by the salt water used to regenerate them.
Make sure:
- the water filling solenoid valve works correctly
- the feed water pressure is at least 50 kPa / 0.5 bar
- the water inlet filter is clean
- the filling solenoid valve filter is clean
- the mother board (ATM-PRES) connector CN2 is correctly positioned.

14 LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS
The parameters listed below, even if present inside the software, cannot be used in appliances currently in
production.
Family
o
o

:

parameter
value

Family
Family
o

- alarm

parameter
, the maximum value it can be set to is 3, but actually the only significant values are 0
and 1. By setting
to 3, alarm F8 may appear, also implemented by the firmware, but not used in
any current application.

DOC. NO. 5956.65J.00

P. 137 / 138

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional

DOC. NO. 5956.65J.00

P. 138 / 138


Download file - link to post